SLK Medical
Founded in year 2006, SLK Technosystems ventured into medical sterilization monitoring products required by Central Sterile Supplies Departments in hospitals, diagnostic laboratories, pharma manufacturing units, sterile medical devices manufacturing units and food industry in the year 2010. SLK Technosystems thus started its distribution arm with all types of sterilization monitoring indicators and medical grade aseptic packaging reels and pouches. SLK further expanded it’s product offerings to Gas Plasma Sterilization Indicators and Tyvek packaging reels.
Over the years, SLK Technosystems has grown its business through all India network of happy customers. We have provided quality products at affordable prices to all our customers by understanding their professional needs and honestly putting our efforts to meet their requirements. This has lead us to gaining customer confidence in our products and services. Our core business principles are offering high quality world class products at affordable prices accompanied with timely after sales Service. We strive to achieve high level of customer satisfaction through all round value addition to our customers.
Today, SLK Technosystems is prominent name as a supplier of sterilization monitoring products in India. We remain humble and endeavor to continue our efforts on these same principles to contribute to better patient care.
Our products comply with highest international standards set by organizations namely AAMI, CDC, WHO, USFDA and ISO.


Steam Indicator Tape - 3/4”x 60 Yds (19mm x 55 mtrs)
Cat No. ST-048
Steam indicator tapes provide immediate identification of processed items while also securing sterilization packs. Colour change indicator verifies exposure to sterilization process. Certified to meet class 1 indicator standards.

AirView Bowie Dick Test Pack
(Air Removal / Steam Penetration Tests)
Cat No. BDS-050 MBD-030
AirView Bowie Dick test pack has instructions for use printed on the box . Test sheet is easy to interpret. Uniform colour change indicates PASS result. Certified to meet AAMI standards for daily air removal and steam penetration test in steam sterilizers and classified as ISO class 2 indicator.


Steam Indicator Strip - 8 ” 250 / Bx - Class 4 Indicator
Cat No. SIL-250
Steam indicator strips provide distinct colour change from blue to black or darker black when exposed to gravity, dynamic air removal and flash cycles. Eight inch strips can be used for larger packs or torn in half at perforation for smaller packs.
STEAMPlus Class 5 Integrator
Cat No. SSI-100
STEAMPlus is an immediate readout Class 5 integrator for use in gravity, dynamic air removal and flash cycles. Four inch strip has distinct pass/fail criteria and allows for easy removal from packs. The STEAMPlus is USFDA cleared as "equivalent in performance to a biological indicator" and offers the highest level of sterility assurance from a chemical indicator. Place integrator inside each pack or in every load (i.e. Middle of the Load or inside the densest pack ) to be sterilized. Release the load if the dark bar on the integrator has entered the SAFE area.


EmPlus™ Steam Emulator Class 6 Integrator
Cat No. EMP-1004 132°C, 4 min
Certified to meet Class 6 chemical indicator standards defined by ISO 11140-1:2005 of steam sterilizer specific cycle.
Reacts to all three parameters Time, Temperature, Saturated Steam at stated cycle.

Steam Indicator Labels - Class 1
Steam Indicator labels are available in a roll of 700 labels. Label dispenser gun available with 2 variations.

SporeView Biological Indicator—STEAM
Cat No. SCS-100 / SCS-106
Biological Indicators ( SCBIs ) provide final results in 24 hours when incubated at 55ºC to 60ºC . Certified to meet BI standards for load monitoring. Removable BI label for record keeping. Conforms to ATCC 7953.


SporeView 10 Biological Indicator—STEAM
Cat No. SVT-050
BIs provide final results in 10 hours when incubated at 55ºC to 60ºC . Certified to meet BI standards for load monitoring. Removable BI label for record keeping . Conforms to ATCC 7953.

SporeAmpule Biological Indicator
Cat No. SA - 020 / SA - 100 / SA - 106
Ideal for monitoring liquid cycles. No vial crushing needed to activate. Purple to yellow colour change indicate sterilizer failure. Final results are available after 48 hours of incubation at 55ºC to 60ºC . Conforms to ATCC 7953.

Dry Block Incubator for Steam SCBI
Cat No. NDB-060E
Calibrated to operate at 60°C for steam BI incubation. Capacity for 15 wells of 11mm each. Compact design uses minimal counter space. Operating voltage 230V.

EO Gas Indicator Tape- 3/4”x 60 Yds (19mm x 55 mtrs)
Cat No. GT-048
EO gas indicator tapes provide immediate identification of processed items. Colour change indicator verifies exposure to EO gas sterilization process. Certified to meet class 1 standards.

EO Gas Chemical Indicator Strip - 8” 250 / Box
Cat No. GIL –250
Certified to meet Class 4 chemical indicator standards for pack monitoring of EO gas sterilizer cycles. Eight inch strips can be used for larger packs or torn in half at perforation for smaller packs.

SporeView Biological Indicator - EO Gas
Cat No. SCG-100 / SCA-100
Biological Indicators (SCBIs) provide final results in 48 hours when incubated at 37ºC. Certified to meet BI standards for load monitoring. Removable BI label for record keeping. Conforms to ATCC 9372.


Sterilization Monitor Strip EO Gas
Cat No. GSM-100
Place EO Gas Sterilization monitor inside each pack to be sterilized. Process the load. All parameters are met when indicator has turned orange. Release the load.

Dry Block Incubator for EO SCBI
Cat No. NDB-037E
Calibrated to operate at 37°C for EO gas BI incubation. Capacity for 15 wells of 11mm each. Compact design uses minimal counter space. Operating voltage 230 V.

SporView®PLUS Biological Indicator Test Pack
Cat No. SBT-025 / SBT-255
- Single-use test for load monitoring steam sterilizer efficacy.
- Certified to meet biological indicator standards for load monitoring of steam sterilizer cycles.
- Includes BI with Class 5 integrator that reacts to all three parameters of sterilization .
- Immediate readout of integrator with wicking style movement.
- 10 hour final BI readout using conventional 55-60°C incubator.
- Removable BI label for accurate record keeping.
- Instructions for Use (IFU) printed on back of each pack.
- Designed to challenge steam prevacuum cycles and steam gravity cycles.
- Certifications of performance with controls.

Sterilization Wraps—STEAM
Cat No. SW-075 / SW-100 / SW-120
Suitable for packaging instrument trays of various sizes for sterilization. Made of non woven fabric. Available in 43 gsm thickness and appropriate looking blue colour. Compatible with Steam, EO and Plasma sterilization processes. Comply with ISO 11607-1 and EN 868-2 norms.

SporView® VH2O2 Biological Indicator (Hydrogen Peroxide SCBI)
Cat No. VH50
Certified to meet BI specifications for hydrogen peroxide sterilization cycle. Final read out in 24 hours when incubated at 55ºC to 60ºC. Conforms to ATCC 7953. Compatible with Sterrad® / Steris ®V-Pro sterilizers.


VH2O2 Chemical Indicator Strip
Cat No. GPS-250R
Certified to meet chemical indicator specifications for pack monitoring of hydrogen peroxide sterilizer cycle. Provides distinct colour change when exposed to H2O2 Sterilizer cycle. Manufactured with synthetic material. Compatible with Sterrad® / Steris ®V-Pro sterilizers.

VH2O2 Chemical Indicator Tape 3/4” x 60 Yds (19mm x 55 mtrs)
Cat No. HT-048
Certified to meet chemical indicator specifications for pack monitoring of hydrogen peroxide sterilizer cycle. Provides distinct colour change when exposed to H2O2 Sterilizer cycle. Manufactured with synthetic material. Compatible with Sterrad® / Steris ®V-Pro sterilizers.

VH2O2 Chemical Indicator Labels
Cat No. GPL2000-R
Certified to meet chemical indicator specifications of hydrogen peroxide sterilizer cycle. Provides distinct colour change when exposed to H2O2 Sterilizer cycle. Compatible with Sterrad® / Steris ®V-Pro sterilizers.

Dry Heat Chemical Indicator Label
Cat No. DIL-1000
Certified to meet chemical indicator specifications for dry heat sterilizer cycle. Provides distinct colour change when processed.


Dry Heat Chemical Indicator Strip
Cat No. DIS-100
Certified to meet chemical indicator specifications for dry heat sterilizer cycle. Provides distinct colour change when processed.

Chemical Process Indicators (CPIs) for monitoring Depyrogenation Process
Cat No. CPI-DP1
CPI-DP1 indicate that the unit has been directly exposed to Depyrogenation process. (High temperature dry heat process)

Dry Heat Sterilization Pouches
Cat No. NSP-400 / NSP-405 / NSP-410 / NSP-420 / NSP-430
Manufactured with nylon material. Clear, strong and puncture resistant. For use with dry heat sterilization process up to 420°F/ 215°C. Multiple self-seal sizes available. Comes with external chemical indicators. MSDS available.

Dry Heat Roll Stock Tubing
Cat No. SN2 / SN3 / SN4 /SN6 / SN12 / SN13 / SN14/ SN16
Manufactured with nylon material. For use with dry heat sterilization process up to 420°F/ 215°C. Available with & without process indicator. MSDS available.

Spore Suspensions and Strips
Cat No. VGS-105 / VGS-106 / VGS-107 / VGS-108 / VGS-109
ATCC 7953 G.Stearothermophilus spore Suspension available with spore population ranging from 10^5 to 10^9. Each pack of 10 ml bottle

Spore Suspensions and Strips
Cat No. VGA-105 / VGA-106 / VGA-107 / VGA-108 / VGA-109
ATCC 9372 B.Atrophaeus spore Suspension available with spore population ranging from 10^5 to 10^9. Each pack of 10 ml bottle

Spore Strips
Cat No. BS-104 to 108 / Cat No. BG-105 to 108
Individual & Dual Spore Strips of G.Stearothermophilus and B.Atropheaus also available ranging from spore population 10^4 to 10^8 against confirmed orders.

Sterilization Reel & Pouches for EO / Steam Process
Medical grade packaging reels are EN 868 compliant / 60 gsm and are available in following sizes. Widths : 5cm / 7.5cm / 10cm / 12.5cm / 15cm / 20cm / 25cm / 30cm / 35cm / 40cm Length : 200 mtr
Pouches are EN 868 compliant / 60 gsm and are available in width from 10cm to 33cm x length 17.5cm to 40cm.
Sterilization reels and pouches are compatible with STEAM & EO gas sterilization process . Process chemical indicators are printed on two sides for easy identification.

Tyvek Flat Reels
Used for sterilization in hydrogen peroxide gas plazma process H2O2. Compatible with Sterrad and Steris V-Pro. Available in following widths.
Widths : 5cm / 7.5cm / 10cm /12.5cm / 15cm / 20cm / 25cm / 30cm / 35cm / 40cm
Length : 70 mtr
Printed with chemical indicator for H2O2 process.

Autoclave Gloves
Very useful for CSSD staff. Helps in handling heated instrument trays, drums, packs etc. while removing them from steam sterilizer. Available in 12” length which extends to cover wrists as well. Full length sleeves also available.

Education & Information
We are equipped with educational tools for the benefit of our customers so that they remain well informed about the infection prevention protocols and CSSD techniques for various sterilization processes. We put our efforts to ensure that all the sterilization practices are understood in right perspective .
Kindly contact us for educational needs at your facility.